Wall U-Value

Thermal transmittance of a layered building element. Layer resistances add in series with the inside and outside surface resistances.

InsulationTS 825Building
↑ ↓ steps the value
Thermal transmittance U0.489W/m²K
Total thermal resistance R_T
2.044 m²K/W
Layer resistances R₁ / R₂ / R₃
0.023 / 0.422 / 1.429 m²K/W
Heat loss Q = U·A·ΔT
98 W
Loss per unit area
9.8 W/m²
METHOD

How it is calculated

R = t / λ      (each layer)
R_T = R_si + ΣR + R_se
U = 1 / R_T      Q = U · A · ΔT
ASSUMPTIONS & NOTES
  • Defaults: 2 cm lime-cement plaster, 19 cm hollow clay brick, 5 cm EPS.
  • For walls TS 825 / ISO 6946 use R_si = 0.13 and R_se = 0.04 m²K/W; the permitted U-value depends on the climate zone.
  • Thermal bridges and condensation are not checked.

Results are for preliminary design and checking; base the final design on the governing standard and safety factors.